F.S.R.S. TABLE 512.A.
PUMPER EQUIPMENT AND HOSE

NOTE: In addition to the following equipment there needs to be 1,200 feet of supply line, 400 feet of it can either be 2 1/2 inch or 3 inch, the remainder may be large diameter hose.

 

Equipment and Hose

Needed

Comments

o

Booster Tank

300 gal.

 
 

Hose:

  

o

Booster (Extra pre-connected 1 1/2-inch house may be substituted for booster hose)

200 ft

 

o

1 1/2 inch: carried

200 ft

 

o

Spare (May be also carried)

400 ft

 

o

2 1/2 inch: spare (may be also carried)

200 ft

 

o

Heavy Stream Appliance (1000 gpm) (Not needed if basic fire flow is less than 1000 gpm)

1

 

o

Distributing Nozzle

1

 

o

Foam Nozzle (1 1/2-inch min)

1

 
 

Foam:

  

o

carried

10 gal

 

o

spare

15 gal

 
 

Nozzles:

  

o

2 1/2-inch playpipe with shutoff

2

 

o

2 1/2-inch straight stream and spray with shut off

2

 

o

1 1/2-inch straight stream and spray with shut off

2

 

o

Breathing equipment (self-contained, 30-minute minimum)

4

 

o

Extra cylinders (carried)

4

 

o

Salvage Covers (12 ft. x 18 ft.)

2

 

o

Electric handlight (4v. wet, 6v dry)

2

 

o

Hose Clamp

1

 

o

Hydrant Hose Gate (2 1/2-inch)

1

 

o

Burst Hose Jacket (2 1/2-inch)

1

 

o

Gated wye (2 1/2 x 1 1/2 x 1 1/2)

1

 
 

Radio:

  

o

Mounted

1

 

o

Portable

1

 
 

Ladders:

  

o

12 or 14 foot roof

1

 

o

24 foot extension

1

 
 

Annual tests:

  

o

Pumper Table 512.b.

1

 

o

Hose Table 512.c.

1

 

All equipment on the list is creditable, not all equipment is needed for the pumper to be creditable.